MCDTV4 Enhanced Transformer Differential Protection

Product detail

Product code:
MCDTV4
Price
Request a quote Select options below to request a price.

Product Information

Download Area

Available options

Documentation (Brochures & Manuals)

Operating Software Smart view: Documentation & Setup

Application

The MCDTV4 offers an all-in-one solution for HV, MV and LV transformers and it offers much more than just a differential protection package.

Furthermore it can detect critical operation states based on voltage measurement (e.g. Overexcitation).

The MCDTV4 provides in addition to that an Interconnection package. This can be used for mains protection at the point of common coupling (e.g. for directional reactive power undervoltage protection).

The integrated backup protection package enables the MCDTV4 to act as backup protection (e.g. for downstream breakers).

Additional features like demand management are available without extra charge.

The protection functions of the MCDTV4 have been adapted to comply with the requirements of the VDE‑AR‑N‑4110:2018.

Functional Overview

MCDTV4 Functional Overview

Approvals

UL File Nr.: E217753

certified regarding UL508 (Industrial Controls)

CSA File Nr.: 251990

certified regarding CSA-C22.2 No. 14 (Industrial Controls)

EAC

certified by EAC (Eurasian Conformity)

  • Complies with IEEE 1547‑2003

  • Amended by IEEE 1547a‑2014

  • Complies with ANSI C37.90‑2005

  • Complies with “Engineering Recommendation G99 Issue 1 Amendment 6 – March 2020”

Key Benefits of the HighPROTEC MCDTV4

  • Wide range power supply: 24 … 270 VDC / 48 … 230 VAC

  • VT measurement from 0 V up to 800 VAC

  • CT measurement always with 1 A and 5 A

  • Plausibility verification intelligence

  • Optimized functional overview by hiding unused functions, parameter and assignments

  • On-board testing without removing the wiring

  • Menu Languages supported: English, German, Spanish, Portuguese, French, Russian, Polish, Romanian


Application

  • Protection of power transformers (HV, MW, LV) against internal phase and ground faults as well as external faults.

Inputs and Outputs
Analog inputs 0 (2)
Analog outputs 0 (2)
Binary inputs 8 (16)
Current transformer inputs 8
Output relays 10
Voltage transformer inputs 4
Watchdog relay 1
Protection ANSI
Voltage protection 27/59
Time overcurrent protection 50/51
Inrush stabilisation (2nd harmonic)
Directional time overcurrent protection 67
Earth fault protection 50N/51N
Sensitive EF isolated/compensated 50Ns/51Ns (Option)
Resistance earthed / solidly earthed 50N/51N
Earth fault directional feature 67N
Thermal replica 49
Circuit breaker failure protection 50BF
Residual voltage 59N
Phase balance 47
Frequency protection 810/81U
Frequency gradient 81
Vector surge / mains decoupling 78V
Power direction 32/37
Negative sequence protection 46
Differential protection: Transformer 87T
Differential protection: Generator 87G
Differential protection: Restricted earth fault 87N
Q->&V< QV
Supervision ANSI
Current transformer supervision 60L
Voltage transformer supervision 60FL
Trip circuit resp. control circuit supervision 74TC
Additional Features
Control and detection of switchgears
Control and supervision of a circuit breaker
Disturbance recorder
Event recorder
Fault recorder (none volatile)
Parameter sets 4
Programmable Logic
Communication
DNP3 RTU (Option)
DNP3 TCP (Option)
IEC 60870-5-103 (Option)
IEC 60870-5-104 (Option)
IEC 61850 (Option)
IRIG-B00X
Modbus (TCP) (Option)
Modbus RTU (Option)
Profibus DP (Option)
Mounting Type
Housing suitable for 19” rack mounting (Option)
Housing suitable for door mounting